ER-MA-8D MEMS Micro Accelerometer

Features:
MEMS silicon capacitive principle;
±2~±200 range;
20000g anti-overload;
LCC20 standard package;
Integrated signal conditioning chip;
Self-test calibration function, SPI standard interface.

Product Details

 

Features:

 

Typical application:

 

Parameter

Unit

ER-MA-8D-02

ER-MA-8D-10

ER-MA-8D-15

ER-MA-8D-30

ER-MA-8D-50

ER-MA-8D-100

ER-MA-8D-150

ER-MA-8D-200

Range

g

±2

±10

±15

±30

±50

±100

±150

±200

Bias

mg

±100

±100

±100

±100

±100

±100

±100

±100

Bias stability(1σ)

mg

≤0.1

≤0.2

≤0.3

≤0.5

≤1

≤3

≤3.5

≤6

Bias repeatability

mg

≤0.06

≤0.2

≤0.3

≤0.45

≤0.5

≤0.5

≤1

≤5

Bias temp. coefficient

mg/℃

≤0.1

≤0.5

≤0.75

≤1.5

≤2

≤5

≤7.5

≤10

Scale factor repeatability

ppm

≤200

≤200

≤200

≤300

≤300

≤500

≤500

≤500

1 year Scale factor stability

ppm

≤200

≤200

≤200

≤300

≤300

≤500

≤500

≤500

Scale factor temp. coefficient

ppm/℃

≤100

≤100

≤100

≤150

≤150

≤200

≤200

≤200

Cross coupling

Mrad

<10

<10

<10

<10

<10

<10

<10

<10


%(max)

<1

<1

<1

<1

<1

<1

<1

<1

Resolution

mg

0.05

0.25

0.5

1

2.5

5

7.5

10

Non-linearity

% of FS

≤±0.1

≤±0.3

≤±0.3

≤±0.3

≤±0.3

≤±0.3

≤±0.5

≤±0.5

Bandwidth

Hz

250

400

400

400

400

400

400

400

Resonant frequency

kHz

1.3

2.7

3.8

4.5

5.8

8.1

10.1

11.4

Start Time

s

1

1

1

1

1

1

1

1

Power consumption

mW

100

Dimensions

mm3

9.0*9.0*2.6

Package


Ceramic package(LCC20)

Output form


Digital output

Operating temperature

-55~125

Storage temperature

-55~125

Impact resistance

g

20000

MEMS Micro accelerometer.jpg

If interested, pls contact us info@ericcointernational.com                                                                    


ERICCO is expert in high quality borehole wireless mwd manufacturing and selling, who is one of the best manufacturers and suppliers of borehole wireless mwd with high precision. We have a professional team at your service.


Inquiry