Dynamic Static Dual Mode Tilt Sensor

ER-F-03 Features:
Static and dynamic dip measurement
Range + 1 to + 90 ° for optiona
resolution ratio 0.01°
Wide voltage input 9~36V

Product Details

ER-F-03 Dynamic Static Dual Mode Tilt Sensor


Introduction
ER-F-03 Dynamic Static Dual Mode Tilt Sensor is an industrial-grade current output inclinometer with integrated dynamic and static two-mode combined algorithm. According to different working environment, the product is automatically switched to dynamic and static measurement mode. Ensure high accuracy measurement in various working environments. When the working environment is in static mode, static algorithm will be adopted in the dipmeter; when the working environment is in dynamic mode, dynamic algorithm will be adopted in the dipmeter, which can not only maintain the static high precision, but also ensure the dynamic high precision measurement of objects. Standard current output 4 ~ 20mA, simultaneously output biaxial sound inclination, can be long distance transmission up to 2000 meters. The attitude parameters (roll and pitch) of the motion carrier can be measured. Output signal strong interference, professional application in the harsh environment of the construction machinery equipment. Products using the latest MEMS sensor production process, the temperature error and made the accurate compensation and nonlinear error correction, the highest accuracy can reach 0.03 ° small range (please refer to product performance more precision index table), high accuracy, small volume, high encapsulation process, to withstand the shock vibration, better product of built-in radio frequency (rf), using electromagnetic interference resistance circuit, especially suitable for application of trenchless underground machinery and other harsh industrial environments. In addition to better technical parameters than common products in the market, the product's reliability and stability are also improved by using high-end application level MCU, three-defense PCB board, imported cable, wide temperature shield metal enclosure and other measures.


features
Static and dynamic dip measurement 
Range + 1 to + 90 ° for optiona 
Resolution ratio 0.01°
Wide voltage input 9~36V 
Output way 4~20mA 
Wide working temperature-40~+85℃
IP67 Protection grad 
High vibration resistance>2000g 
Size 72.62×42×23.1mm(can be customized)


Application
Leveling of engineering vehicles 
Bridge and dam monitoring
High altitude platform safety protection
Medical device Angle control 
Attitude navigation of underground drill 
Shield pipe jacking application
Directional measurement based on dip Angle
Slope monitoring of geological equipment 
Measurement of pitch Angle of directional satellite communication antenna
Mining machinery, oil drilling equipment 
Equipment level control 
Registration control, bending control


Specifications

Parameter

Conditions

ER-F-03-10

ER-F-03-30

ER-F-03-60

ER-F-03-90

Unit

Range of measurement


±10

±30

±60

±90

°

Measurement axis


XaxisYaxis

XaxisYaxis

XaxisYaxis

XaxisYaxis


Zero output

0°output

12

12

12

12

mA

Resolution ratio


0.01

0.01

0.01

0.01

°

Static accuracy

@25℃

0.02

0.05

0.08

0.1

°

Dynamic accuracy

@25℃

0.1

0.2

0.3

0.5

°

Long-time stability


0.05

0.05

0.05

0.05


Zero temperature coefficient

-40~85°C

±0.006

±0.006

±0.006

±0.006

°/℃

Temperature coefficient of flexibility

-40~85°C

≤100

≤100

≤100

≤100

ppm/℃

Poweron start time


0.5

0.5

0.5

0.5

S

Response time


0.02

0.02

0.02

0.02

s

Response frequency


1~20

1~20

1~20

1~20

Hz

Electromagnetic compatibility

According toEN61000 andGBT17626

MTBF

≥50000 h/t

Insulation resistance

≥100 M

Impact resistant

100g@11ms、Three axis and with(A half sine wave)

Anti-Vibration

10grms、10~1000Hz

Waterprooflevel

IP67

Cable

Standard 1 m length, wear - resistant, oil - proof, wide temperature, shielded cable4*0.4mm2

Weight

120g(not include cable)

The performance parameters of the list only ± 10 °, ±30 °, ± 60 °, ±90 ° series for reference, other measuring range in the adjacent parameters for reference, please.


Electrical parameters of products


Parameter

ConditionsMinimumTypicalMaximumUnit

The power supply voltage

Standard

9

12、24

36

V

Working current



50


mA

output load

resistive


400

1000

Working temperature


-40


+85

Storage temperature


-55


+125


Product mechanical parameters
Onnectors: 1m straight leads (customizable)
Protection class: IP67
Material: aluminum alloy grinding sand oxidation
Installation: three M4 screws

Operating principle
The core control unit imported from Europe is adopted.Using the principle of earth gravity, when the inclined Angle unit is tilted, the earth gravity will produce the component of gravity in the corresponding pendulum hammer, and the corresponding capacitance will change. Through amplification, filtering and transformation of the capacitance, the inclination can be obtained.


FAQ:


1. What is your quotation condition?

If you have DHL or Fedex account ,we can quote EXW price ,otherwise CIF or FOB price.


2.Do you have any discount when procurement? 

We will quote sample price at first and we will quote volume price if you need more quantity.


3.How long is the delivery time?

For sensors,parts,modules : in stock-one week;no stock-2-4weeks; For systems,generally ,8-12 weeks.


4.How to deal with the quality problems?

If confirmation of product quality problem we can replace it freely for customer in the shortest period.


If interested in Dynamic Static Dual Mode Tilt Sensor, pls contact us : info@ericcointernational.com

Inquiry